The multi pass test stand is mainly used for testing the performance of hydraulic filters according to ISO 19438, ISO 4548-12 and ISO 16889 standards. These standards describe a method for determining the contaminant capacity, particle removal and differential pressure characteristics of filter elements. In order to determine such characteristics, filter elements are injected with continuous contaminant (test dust), whereas online particle sensors measure the contamination, thus making the evaluation of the filter element's performance possible.
This test stand is automatically controlled by a computer; the flow chart and all the test parameters can be displayed on the screen. Data handling and generation of reports according to the standards mentioned above are included.
The test stand is designed as a Multi Pass Test Stand acc. to ISO 19438, ISO 16889 and ISO 4548-12, as a part of the filter manufacturing and quality monitoring center.
Following tests can be performed with this test stand:
This test stand can be also configured and quoted according to your individual specifications.
Flow range: | 3 loops: 0,5-4 l/min, 3-30 l/min and 28-250 l/min |
Minimal system pressure: | 4,5 bar |
Differential pressure: | 16 bar |
Maximal system pressure: | 25 bar |
Hydraulic fluid: | MIL H 5606 or similar |
Viscosity: | 13,2 mm²/s by 40°C |
Dosing pump | 50–250 ml/min |
Maximal deluding: | 1:5 (25 ml/min sample flow) |
Particle counter: | online particle counter (Pamas) 4 µm(c) calibrated per ISO 11171 optional 1,5 - 20 µm |
Test tank: | 100 l |
Restore tank: | 160 l |
Dosing tank: | 70 l |
Test head for flat sheets: | 200 cm² (max. 16 bar) |